View Test
Test: Lumbar Rotation - Active
Video Link
Background/Purpose
Procedure
Subject stands arms at sides. Clinician places compas/goniometers in transverse plane at T12 and sacrum and zeroes them. Instruct the subject to rotate to the right. Subtract the T12 value from the sacral value. Typical measures are 3-18 degrees
Performed: Unilaterally
Dialog
Lumbar rotation measurement.Criteria
- Pain free
- 3-18 degrees
Measurement
3-18 degrreesLOINC Code
0Scale/Grading
Pass/FailTest Stats
-
Side Pass Fail Left 1 0 Right 0 1 Avg. Measure. Left 0.0 0.0 Avg. Measure. - Right 0.0 5.0